220V Hotels Portable Refrigerated Industrial Spot Coolers Spot AC Unit For Resort

1 Piece
MOQ
$488.00(1 - 9 Pieces) $420.00(10 - 29 Pieces) $400.00(>=30 Pieces)
цена
220V Hotels Portable Refrigerated Industrial Spot Coolers Spot AC Unit For Resort
Характеристики Галерея Характер продукции Спросите цитату
Характеристики
Характеристики
Applicable Industries: Hotels, Garment Shops, Building Material Shops, Machinery Repair Shops, Manufacturing Plant, Food & Beverage Factory, Farms, Restaurant, Home Use, Retail, Food Shop, Printing Shops, Construction works , Energy & Mining, Food & Bevera
Condition: New
Type: AIR COOLER
Operating Voltage: 220v
Mounting: Floor Standing
Warranty: 1 Year
Dimension(L*W*H): 450mm*510mm*1100mm
Key Selling Points: Competitive Price
Airflow: 11900BTU
Machinery Test Report: Provided
Video outgoing-inspection: Not Available
Warranty of core components: 1 Year
Core Components: compressor
Weight (KG): 60 KG
Cooling capacity: 3500W/11900BTU
Color: White Blue
Refrigerant: R410A
Noise: 55db
Power supply: 220V/ AC/50HZ
Compressor: Toshiba
Water Tank: 14L
Cooling/Heating: Cooling
Cold air removal: 480m3/h
Showroom Location: None
Marketing Type: New Product 2020
Основная информация
Оплата и доставка Условия
Packaging Details: carton
Характер продукции

HOW TO CHOOSE INDUSTRIAL AIR COOLER?

1) Collig of workshop
A.If workers are in a fixed production line, it is recommended to choose QD-150 or QD-180 two large models,The cold air is delivered to each post through the external cold air pipe to achieve post re- frigeration, energy saving and thehighest efficiency.
B.If the staff positions are scattered,It is recommended to choose QD-35 or QD-55 models with better
mobility,Double outlet ducts can cool multiple people at two positions at the same time, with the highest efficiency.
2) Cooing the computer room
A.Generally, the computer room is cooled as a whole,so the temperature control requirements are relatively high,and the cost is relatively high.If you want to choose an industrial air conditioner, first do not choose a water chiller, wet curtain air
cooler,Because this type of air coolerwill greatly increase the environmentalh. umidity,affect the normal operation of the
machine,and the cooling temperature difference is relatively small,
B.Choose the industrial air conditioner provided by QIDAMAX. It is recommended that you choose the QD-35 model. This air conditioner has alarqe air volume and alarge cooling temperature difference.It can cool acertain part of the computer room at a fixed point, and has a dehumidification function, which requires the overall environmental cooling. The hot air can also be directed outdoors without affecting the overall temperature.
3) Cooling of agricultural farms
Used for cooling in agricultural greenhouses or breeding industry,It is recommended to choose largemodels such as QD-150, QD-180, or QIDAMAX according to your specific requirements to determine the air conditioner. The air conditioner is placed outdoors and delivers cold air to the room.

7CORE ADVANTAGES:

1. Toshiba compressor has stable performance and low failure rate;
2. High-efficiency evaporator and condenser;
3. Lightweight, flexible, easy to use, and free to move;
4. No need to install, plug and play;
5. Integrated body design, cooling + dehumidification function;
6. High quality, uniform air flow and low noise;
7. Fully automatic control, adjustable humidity
1
Model
QD-35M

2
Power supple
220V AC/50HZ

3
Cooling capacity
3500W/11900BTU

4
Air volume selection
Strong
Weak
5
Cold air discharge
480m3/h
420m3/h
6
Warm air discharge
1200m3/h

7
Rated current
6.6A
6.4A
8
Maximum current
7.4A

9
Power comsamption
1400W
1360W
10
Maximum power consumption
1500W
11
Compressor
Fully enclosed rotany/
Toshiba compressor
12
Condensate treatment method
14L bucket
13
Refrigerant
R410A
14
Refrigerant jnjection
530g
15
Exhaust pressure
3.0MPa
16
Suction pressure
0.9MPa
17
Operating pressure
3.7MPa
18
Use environment
18OC~45OC
19
Dimensions
450mm×510mm×1100mm
20
N.W(kg)
60kg

FEATURES

1)All steel shell,Comes with universal wheel,strong and sturdy,Lightweight and flexible.
2) Wind volume,Strong refrigeration,Low energy consumption,long life,Running smoothly.
3) Use advanced R410A refrigerant,Green, environmentally friendly, healthy and comfortable.
4)Use advanced imported compressor,t can be effectively refrigerated under 45℃ high temperature environment.
5)Use a fully automatic control system,With automatic diagnosis function,Effectively prevent damage to the machine due to bad operations and other conditions.

FAQ

Q1: Are you manufacturer or trading company?
A1: We are manufacturing factory + trade integration with more than 15years production experience in this field and 5 years exporting experience.

Q2: Can I get samples?
A2:Yes we can provide samples, client need pay the sample fees and express charge.

Q3: Is it possible to make our logo on the product?
A3: OEM and ODM is available, including special design,color, logo, packing etc.

Q4: Can I get any discount?
A4: The price is negotiable, we can offer you discount according to your order quantity.

Q5: What is the process of an order?
A5: Making artwork and design drawing---making samples---samples test---mass production---finished product inspection---packing

Q6: What is your delivery period?
A6: Generally around 10-25days. If we have inventory, we can arrange shipment within 3days.(Only need time to change the plug and do the pre-shipment test) Also, production lead time depends on specific items and quantity.

Q7: What about the warranty-after sales service?
A7: We offer 1 year warranty for our machines.We have after-sales department for 24hours consultation service.

FIVE STEPS TO SEASONAL MAINTENANCE OF INDUSTRIAL AIR CONDITIONERS:

Pre-season maintenance:
Before the start of the season, check whether there are obstructions around the unit and the air inlet.
Unit use and maintenance:
Pay attention to the cleaning of the chassis, and press the "clean" button to clean it every day to prevent bacteria and odor from occurring.
Periodic maintenance of the unit:
The unit runs for 1-2 months. If the wet curtain, filter screen is blocked or the chassis is too dirty, it should be cleaned in
time to avoid machine failure.
End of season maintenance:
In order to prevent freezing damage to the body and mosquito breeding, the tap water should be turned off when it is not used for a long time, and then press the cleaning button to drain the water, and cut off the power supply.
The internal cleaning of the unit:
If the unit runs for a long time, in order to ensure the cooling effect, the inside of the unit must be cleaned once a month or
two.